Gabungan AC SPD Type 1 lan Type 2 Lightning Current Arrester lan Surge Arrester digunakake kanggo proteksi kilat langsung ing sistem Daya, lan bisa digunakake ing sisih voltase rendah Transformer.

Model:YL2-C50-12.5M

Kirim Pitakonan

Deskripsi Produk

Gabungan AC SPD Tipe 1 lan Tipe 2 Lightning Current Arrester lan Surge Arrester
  

INFORMASI UMUM

●Varistor surge protective device (AC SPD)
●Gabungan SPD Tipe 1&2 kanthi teknologi MOV lan CDGG kanggo digunakake ing sistem daya sing beda.
● Indikasi visual lan sinyal kontak remot opsional (S), bisa nglindhungi peralatan Terminal.
●Non-follow saiki.
●Unit lengkap Prewired sing kasusun saka bagean dhasar lan modul proteksi plug-in sing bisa diganti.
●Pemasangan ing wates saka zona LPZ 0A nganti LPZ 2.
●Pasang ing wates zona LPZ1 lan LPZ2
● Gunakake kanggo pangayoman kilat langsung ing sistem Power, bisa panggunaan ing Transformer kurang-voltase sisih.
● DIN ril instalasi.

GAMBAR DIMENSI

SPESIFIKASI
Model YL2-C50-12.5M 2P YL2-C50-12.5M 3P YL2-C50-12.5M 4P
SPD miturut EN 61643-11 / IEC 61643-11 Ketik 1+2/ Kelas Ⅰ+Ⅱ Ketik 1+2/ Kelas Ⅰ+Ⅱ Ketik 1+2/ Kelas Ⅰ+Ⅱ
Maks. tegangan operasi terus-terusan (a.c.) (Uc) 385V (50/60Hz) 385V (50/60Hz) 385V (50/60Hz)
Overvoltage sementara (TOV) 385V / 5s-tahan 385V / 5s-tahan 385V / 5s-tahan
Arus impuls kilat (10/350µs) (Iimp) 12.5kA 12.5kA 12.5kA
Arus debit nominal (8/20µs) (In) 20kA 20kA 20kA
Maks. arus discharge (8/20µs) (Imax) 50kA 50kA 50kA
Tingkat perlindungan voltase (Munggah) ≤2.2kV ≤2.2kV ≤2.2kV
Wektu tanggap (ta) ≤25ns ≤25ns ≤25ns
Maks. Sekring serep ≤160A gL/gG ≤160A gL/gG ≤160A gL/gG
Rating arus hubung singkat (Iscr) 25kArms 25kArms 25kArms
Kisaran suhu operasi (Tu) -40℃...+80℃ -40℃...+80℃ -40℃...+80℃
Status operasi / indikasi kesalahan Ijo (apik) / Abang (ganti) Ijo (apik) / Abang (ganti) Ijo (apik) / Abang (ganti)
Kanggo dipasang ing Rel DIN 35mm acc. kanggo EN 60715 Rel DIN 35mm acc. kanggo EN 60715 Rel DIN 35mm acc. kanggo EN 60715
Area cross-sectional (Min.) 4 mm2 4 mm2 4 mm2
Area cross-sectional (Maks.) 35 mm2 35 mm2 35 mm2
Stripping Length / Tightening torsi 10mm/3Nm 10mm/3Nm 10mm/3Nm
Bahan kandang Termoplastik, UL 94 V-0 Termoplastik, UL 94 V-0 Termoplastik, UL 94 V-0
Panggonan instalasi Instalasi njero ruangan Instalasi njero ruangan Instalasi njero ruangan
Derajat pangayoman IP 20 IP 20 IP 20
Demensia (L*H*W) 90mm * 36mm * 82mm 90mm * 54mm * 82mm 90mm * 72mm * 82mm
Hot Tags: Gabungan AC SPD Tipe 1 lan Tipe 2 Lightning Current Arrester lan Surge Arrester, Grosir, Tuku, China, Diskon, Kualitas, Rega Murah, Tuku Diskon, Produsen, Pemasok, Pabrik, Ing Simpenan, Sampel Gratis, Made in China, CE, 2 Garansi taun, jual panas, jual panas, Jual Langsung Pabrik, Pasokan Langsung Pabrik

Kategori sing gegandhengan

Kirim Pitakonan

Mangga bebas menehi pitakon ing formulir ing ngisor iki. Kita bakal mangsuli sampeyan ing 24 jam.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
Reject Accept